General Introduction

Tokyo Keiso FW-9000NN Servo Tank Level Transmitter is the successor to the well received and widely used FW-9000 series for its reliability and variety of long term application. Using the most of reliable, durable and highly accurate mechanism of FW-9000, FW9000NN has become more reliable and user-friendly by introducing up-dated electronics etc (SIL2 compatible). Consequently, FW9000NN has the interchangeability with the current FW-9000 series in terms of installation methods and interfaces with other equipment. Its noise resistivity and lightening protection performance have been improved significantly. The intensified automatic self-diagnosis and self-adjustment functions have made FW9000NN more user-friendly. Including ATEX certified version intended for use in potentially ex-plosive atmosphere FW9000NN is ready to serve world-wide users.

Added or improved features from existing models are listed as follows:

1.1 For bonded tanks
The increased noise resistivity and lightening protection assure you reliable operation as complying with superb level 4 or more stipulated in IEC61000-4,5.

1.2 Complying with RoHS requirements.

1.3 Having the same dimensions and materials as existing models, FW9000NN is compatible to Japanese explosion-proof requirements and is interchangeable with existing FW-9000 to make replacement easy.

1.4 Parameters can be set without opening housing with 4 magnet sensors attached to the indicating windows.

1.5 Compatible with wide range of power supply from 100 to 240 VAC, 50/60Hz.

1.6 Power source of 100 to 240 VAC 50/60Hz is acceptable

1.7 Standard 2 sizes of measuring drums cover wide measuring ranges from small to gigantic tanks

- Eco-friendly low power consumption as small as Max. 25VA.

- Covers high design pressure up to 3.0 MPa.

- Electronic circuits are installed in the electric compartment which is completely isolated from drum compartment.

-  Can be connected to the existing spot type and multipoint aver-aging temperature sensors.

- Precision stepping motor control with micro processor has realized amazingly accurate measurement.

- Highly reliable operation with powerful self-diagnosis functions (SIL2).

- High durability with non-contact type balancer without using slip ring.

- In has addition to the high-speed serial data communication, FW9000NN have various communication tools which are com-patible to TOKYO KEISO's existing well-established transmitters. Therefore, FW-9000NN serves with ease for your renovation and replacement of the existing tank monitoring system.

- In combination with DIR110NN series, Max. 6 contact signals transmitted between field and control room. Monitoring and con-trol of equipments around the tank yard are also possible in addi-tion to liquid level measurement.

- 4 to 20 mA signals such as pressure signal can be digitalized and retransmitted

- Analog 4 to 20mA signals such as level and temperature can be output additionally to meet with high speed data processing car-ried by host computers.

2. Short Specifications

Model

FW-9000NN

Liquid level
  detection methods

Digital controlled electric servo   balancing type consisting of small size displacer, measuring wire and wire   drum

Measuring range

Maximum: 60m

Temperature

Liquid: -200 to +300ºC

Ambient: -20 to +55ºC (Temperature of main body)

However, the liquid and the moisture   inside the wire drum room shall not freeze over, nor adhere

*Not suitable for the use environment   where the mass of displacer changes.

Pressure

Max: 3MPa

Accuracy

(1) Liquid level measurement: ±1.0mm

(2) Interface measurement In case of   density difference of 0.2g/cm³: ±(2.7)mm

(3) Density measurement: ±0.01g/cm³

Process
  connection

3", 4", 5", 6"   JIS5K/10K/20K/30KRF, ANSI150/300,

JPI150/300 Flange connection

Displacer   guiding

Stand pipe method as standard,

Non-guiding and guide wire methods as an   option

Inputs

a. Temperature: Pt100Ω spot temp.   sensor, Average temp. sensor, Multi-spot average temp. senor

b. Analog signal: 4 to 20mA DC 1point.   Conversion accuracy ±0.5% F.S.

Outputs

a. Serial data output to control room

b. Serial data output to explosion-proof   tank side receiver

c. Contact outputs Numbers of contacts:   2 Combination: SPST (1a or 1b)

d. Analog outputs: 2 points of 4 to   20mADC for level and temperature

Presentation

2 indication parts by LCD

Enclosure

Water-tight (FW-9····NW) or   Flameproof Exd II CT6 (FW-9····NE)

Power supply

AC100 to 240V、50/60Hz

Consumption

Maximum 25VA

3. Basic Code Selection of FW-9000NN

Main

Code

Suffix Codes

Description

FW9






Always FW9

Measuring range

1





0 to 5m

2





0 to 10m

3





0 to 15m

4





0 to 18m

5





0 to 25m

6





0 to 30m

7





0 to 40m

8





0 to 60m

9





Special

Wire drum size


1




400mm


2




800mm


9




Special

Pressure rating



1



Atmospheric



2



0 to 1 Mpa



3



0 to 2 Mpa



4



0 to 3 Mpa



9



Special

NN




NN


Always NN

Enclosure





1

Weather proof





2

Flame proof